The Kipp & Zonen CNR 2 measures net shortwave and net longwave radiation and provides separate outputs for each radiation type.
 
NET RADIOMETER

     Model CNR2:

$2600

   
 
  MOUNTING THE
SENSOR

Mount the sensor out and away from the mounting device to minimize interference. The mounting device must provide rigid and stable support for the sensor.

The sensor should be mounted level, with the cable and rod oriented towards the nearest pole, and where it has an unobstructed view of the horizon. It should also be kept away from any heat sources.

The sensor is typically mounted at a height of 1.5 to 2.5 meters.